Home / Our Services / Products / Tank equipment

Tank equipment

Manway, standard design

 

- manway lid with quick-action lock

- with rubber toggles, corrotion proof

- nominal diamer DN 500, DN 600 and DN 800


alternatively:


manway with pressure-relief lid for emergency use

Manway, gastight design

 

- manway lid bolted

- with o-ring and bolts from stainless steel

- nomial diameter DN 500, DN 600 and DN 800


alternatively:


manway, liquid-tight for installation in the cylindrical wall section

Nozzles (installed in tank roof or cylindrical wall) with bushing and backing flange

 

- hole pattern acc. to DIN 2501, DIN 2633, ANSI B16.5

with thread adaptor and sleeve nut


- connection sizes acc. to DIN 16963-15

with female thread


- pipe thread acc. to DIN ISO 228, DIN 2999

ventilation nozzle


- with 180° pipe bend, optional with filter grating

Liquid level gauge

 

with floater from HDPE inside tank and outside counter weight from red UPVC, incl. clear-transparent guide pipe


- floater removable straight thru the nozzle

- gastight design with condensate outlet available

- bistable change-over contacts available

- inkluding metering bar, pitch and labeling in m³


alternatively:


Electronic liquid level measurement (ultrasonic, radar, etc.)

Liquid level limit switch acc. German Water Law

 

Filling level probe as overfilling prevention acc. law with DIBt-Approval, constructed as ring floater with permanent magnet and reed contact inside quide pipe.


The set consisting of ring floating switch together with a control unit (optial-acoustic alarm) or measuring transducer for cabinet installation builds a approved device acc. to German Water Law.

Leckage alarm acc. German Water Law

 

Filling level probe as leckage alarm acc. law with DIBt-Approval, constructed as ring floater with permanent magnet and reed contact inside quide pipe.


The set consisting of ring floating switch together with a control unit (optial-acoustic alarm) or measuring transducer for cabinet installation builds a approved device acc. to German Water Law.

Heating coil from stainless steel 316 for use with warmwater, installed in a storage tank from HDPE

 

we provide the following storage-tank heatings


- heating pipes from PP or stainless steel

- electrical immersion heaters from stainless steel or titan

- electrical immersion heaters from PTFE or PP

- surface heatings on the tank outside from self limiting safety heating cable on polymer basis for optimized energy consumption we provide suitable tank isolations, e. g. from polyurethane foam

Protection collar from HDPE to cover the ring gap

 

between storage tank and secondary containment for protection against rain, snow or dust.

The protection collar could be slipped into a guiding profile, which is welded to the tank in our factory.

The time-consuming welding of the protection collar to the tank on the construction site becomes obsolete, as well as setting up a scaffolding around the tank.

Deformation of pre-mounted protection collars during transport are also things of the past.

Overpressure / underpressure safety device

 

Build as ball valve for reliable protection of storage tanks against damage due to excessive pressure while charging or discharging the storage tank.

Tank platform with circumferential handrail

 

and circular service platform with steel grating and vertical ladder, optional with safety cage.


Made from galvanized steel or stainless steel according to the German Accident Prevention Regulations (UVV).


alternatively:


Vertical ladder with ladder exit (approx. 500 x 500 mm) optional with safety cage depending on ladder height

We use cookies

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.